Horizontal exits a solution to Egress challenges

分享这篇文章

2019年4月10日

Proper egress analysis is an extremely important aspect of 消防安全设计 that not only involves following applicable codes, but also careful coordination with the project architect. International Building Code (IBC) defines an 可访问的 means of egress as a “continuous and unobstructed way of egress travel from any point in a building or facility that provides an 可访问的 route to an area of refuge, a horizontal exit or a public way.” Adequate means of egress can vary depending on the use of the building and the occupancy load. Facilities with large occupancy loads can present challenging egress design, specifically if the existing building is being retrofitted to accommodate a change of use to contain that larger load. Frequently, the existing exit capacity provided on each floor is not adequate for the new occupancy.

什么是水平退出? A Definition and How Can It Help

For facilities with large occupancy loads or those that must be retrofitted, designing and constructing a horizontal exit may be the best solution for providing the required egress capacity. Horizontal exits are designed to create a safe refuge area separated from the fire area by a two-hour fire-resistance-rated separation. It is recognized in accordance with the 2015 IBC and/or the 2015 NFPA 101, 生命安全守则.

A 现实的例子

One of our recent projects involved a new tenant space within an existing high-rise office building, which was being retrofitted to include offices and large assembly/conference areas. The tenant space had two existing exit stairs that provided a maximum exit capacity of 440 occupants. The new occupant load of the tenant space would exceed 500, requiring a third exit and additional exit capacity in accordance with the applicable codes.

为了实现这个目标, we needed to maintain a separate level of security for office spaces from the assembly areas. The public would often use assembly areas for events, which meant the office areas had to be kept secure, only allowing entrance for employees by way of a swipe card. The design of the refuge area could not extend into the office spaces and had to be contained within the common areas of the building.

使用水平退出方案, we designed an exit that included a two-hour separation through the tenant space creating separate compartments with an available exit stair on each side. We based the refuge area on the capacity available by the horizontal exit doors. This horizontal exit solution solved the client’s egress dilemma efficaciously.